Previous Page  10-11 / 22 Next Page
Information
Show Menu
Previous Page 10-11 / 22 Next Page
Page Background

TEST 4

The Issue -

TABO - Mechanical Insertion Machine

The Test -

The coffin is tested by loading onto equipment to

simulate a TABO charger

The TABO charger only exists in a dozen or so crematoria, but none the less,

suppliers understand that once the coffin is sold, they don’t know where it is

going to ends up.

On equipment to replicate the TABO charger, check the coffins

performance. If it snags or sags on loading pins, it fails.

TEST 5

The Issue -

Ignition/radiant heat scenario

The Test -

A sample of the coffin

is tested by subjecting it to

a variation of temperatures to simulate the cremator when the

access doors to the chamber is opened.

When the Coffin is presented for cremation, the cremator door opens and

it’s exposed to very high temperatures. The Coffin cannot catch fire until it is

securely in the cremation chamber.

Test sample material. They expose the sample to the heat source for

a given length of time and temperature. If it catches fire, it fails

550 °C

550 °C